PRODUCT_LINE: BCM ============================================ Software Update Name: BCM360.334-UM Applicable H/W Platforms: BCM200, BCM400, BCM1000, SRG200 1.0, SRG400 1.0 Applicable S/W Platforms: BCM 3.6, SRG 1.0 based on BCM 3.6 Category: GEN Installation Recommendations: This patch should be applied to all new installs of BCM 3.6 and SRG 1.0 based on BCM 3.6. Existing installations should have this patch applied if they are experiencing any of the issues that are corrected. There is no need to schedule specific maintenance to apply this upgrade if there are no reported issues. In those cases, systems should be updated at the next regular service opportunity. Component & Version: Unified Manager 3.6.0.0.2.1 Dependencies: Required patches - Cumulative Patch #3 BCM360.259-CUMULATIVE-Patch#3 or later version BCM360.325-CTI or later version Product Dependencies - None Size: 1.4 MB System Impact: time to apply patch ~ 20 minutes Does patch application force reboot: Yes Other: None Limitations: Patch BCM360.325-CTI or later version is required for the full functionality of the new prompt. Patch Removable: No Description: ----------- The following issue is addressed: 1. BCM 3.6 - DTMF Tones not recognized by BCM Call Pilot when simulatenously received both in-band and out-of-band This patch introduces a new drop-down combo box on the page Services->IP Telephony->IP Trunks->H323 Trunks->Local Gateway IP Interface, with the label "Ignore in-band DTMF in RTP". The drop-down combo box has two options, "Enabled" and "Disabled" (default). Using this setting, Voice CTI decides to ignore or to consider the in-band DTMF digits received over a VoIP call. Q01314181-04 This patch includes the content of the following superseded patches: BCM_360.278_UM.39.1009 ---------------------- 1. The BCM can be used as a DHCP server for a CSE1000. We can change option 128 in the Global settings in the DHCP page of Unified Manager to use port 4100 instead of 7000. This works, but when you reboot the BCM, the option changes back to port 7000. Q01106118 2. This fix displays a message for the user to reboot the BCM whenever BCM DHCP config is changed from server to relay agent or vice versa. This reboot message is needed due to the fix for the CR Q00979221, which had changes in mspQoS to do some special processing when BCM is relay agent. Q01153688 BCM 360.007 UM.39.1001 ---------------------- 1. Q00881489: Incremental Payloads control is missing in unified manager 2. Q00907581: BCM 3.5 does not show all the remote gateways programmed. (Only 25 of them) BCM_360.082_UM.39.1003 ---------------------- 1. Q00907581 - BCM 3.5 does not show all the remote gateways programmed. (Only 25 of them) 2. Q00881489 - "Incremental Payload Size" control is missing in unified manager 3. Q00944339 - LAN1 and 2 goes down after restarting the router with patch 4. Q00944340 - LED's keep on Blinking after applying patch BCM_350.011_UM.39.1002-LAN Down 5. Q00956906 - ISDN Link doesn't establish after applying the patch BCM_350.011_UM.39.1002 6. Q00935053 - BCM crashes when multiple connections on same Callback user 7. Q00934446 - BT Norstar/RAS Callback not working correctly BCM_360.184_UM.39.1006 ---------------------- 1. Q01103195 - G729 Payload displayed as 0ms after CP2 applied BCM_360.239_UM3.39.001 ---------------------- 2. Q01220182 - BCM - 10.10.15.1 and 10.10.15.0 appear in the routing table.