PRODUCT_LINE: BCM50 ============================================ Software Update Name: BCM050.115-MONIT-DIALOGGER-SCD Applicable H/W Platforms: BCM50, BCM50a, BCM50e, SRG50 Applicable S/W Platforms: 1.00.2.04g, 1.00.2.04j, SRG50 Category: GEN Installation Recommendations: This patch should be applied to all new installs of BCM50 R1 and SRG50. Existing installations should have this patch applied if they are experiencing any of the issues that are corrected. There is no need to schedule specific maintenance to apply this upgrade if there are no reported issues. In those cases, systems should be updated at the next regular service opportunity. This patch corrects a number of BCM50 R1 and SRG50 alarm deficiencies identified in final alarms verification testing. The patch eliminates generation of multiple alarms caused by the same fault event and ensures that only the alarm pointing to the root cause of the fault event is generated and displayed, thus reducing the number of unnecessary alarms. It is recommended that this patch be applied to any system being monitored using alarms and/or SNMP. Component & Version: dialogger-2.04.1-3.ppc.rpm monit-4.4-9.ppc.rpm scd-2.04.3-1.ppc.rpm Dependencies: Required patches - BCM050.096-Service Update #2 Product Dependencies - None Size: 0.7 MB System Impact: time to apply approximately 1 minute Does patch application force reboot: No Other: None Limitations: All alarms previously shown in the Element Manager Alarm panel (Administration > General > Alarms) will be cleared after the patch is applied. Historical alarms will be available in the alarm log. Also, any previously-customized alarm settings (Administration > General > Alarm Settings) will be lost after applying this patch, and will have to be manually re-configured. Patch Removable: Yes Description: ----------- The following issues are addressed: 1. Alarm 391 cannot be generated for UTPS packet loss on IP terminal Q01137772 2. Time Service Event 6003 Inactive on BCM50 REL1 Q01136800 3. "BRIM is primary clock instead of DTM" alarm NOT reported when DTM-PRI is used Q01133248 4. Grammar Error on GUI, SNMP text string for PSM Event 11409 Q01136341 5. USB failure alarms need more detail in resolution field or in description field Q01139367 6. AlarmID 17015 generated when enable or disable modem using SSBA Q01158634 7. SNMP strings\EM alarms for Local\Remote Temps not equal to Master Alarms List Q01132292 8. Monit not generating recovery message when you killall CoreTel Q01071084 This patch includes the content of the following superseded patches: None. Installation Recommendations: This patch should be applied to all new installs of BCM50 R1 and SRG50. Existing installations should have this patch applied if they are experiencing any of the issues that are corrected. There is no need to schedule specific maintenance to apply this upgrade if there are no reported issues. In those cases, systems should be updated at the next regular service opportunity. This patch corrects a number of BCM50 R1 and SRG50 alarm deficiencies identified in final alarms verification testing. The patch eliminates generation of multiple alarms caused by the same fault event and ensures that only the alarm pointing to the root cause of the fault event is generated and displayed, thus reducing the number of unnecessary alarms. It is recommended that this patch be applied to any system being monitored using alarms and/or SNMP. Limitations: All alarms previously shown in the Element Manager Alarm panel (Administration > General > Alarms) will be cleared after the patch is applied. Historical alarms will be available in the alarm log. Also, any previously-customized alarm settings (Administration > General > Alarm Settings) will be lost after applying this patch, and will have to be manually re-configured.