PRODUCT_LINE: BCM50R3 ============================================ TITLE ===== BCM50.BCM50e.002 v2.6.0.0.009b1 ======================== Release: 2.6 Issue: N/A Category: GEN Superceded By: NONE Release Date: 20080429 Patch Conflict(s): N/A Special Instructions: NO Patch Version: N/A ======================== Software Update Name: BCM50.BCM50e.002 Applicable H/W Platforms: BCM50e R2 and BCM50e R3 Integrated Business Secure Routers Applicable S/W Platforms: 2.6.0.0.007 and earlier Category: GEN Installation Recommendations: This update should be applied to all new installations of BCM50e R2 and BCM50e R3 Integrated Business Routers. Existing installations should have this update applied if they are experiencing any of the issues that have been corrected. Component & Version: BCM50.BCM50e.002 v2.6.0.0.009b1 Dependencies: Required Updates - None Product Dependencies - None Size: 2.7 MB System Impact: System requires a reboot after the firmware is uploaded. Does update application force reboot: Yes Other impacts: None Limitations: None Update Removable: Yes Description: ----------- The following issues are addressed: Device freezes every few hours when a NAT enabled CVC Termination is active. Q01803112 This update includes the content of the following superseded updates: BCM50r2.BCM50e.001 ------------------------------- Some new Denial of Service attacks could disrupt data service. Q01502213 The router could reboot in some configurations with multiple tunnels. Q01584155 When all traffic is routed through the Bandwidth Manager, reboots could occur. Q01591900 Traffic outside of a split tunnel would not be sent if tunnel negotiation started, but failed. Q01615393 If an error is made in the Static Route GUI, the error message could not be closed. Q01661800 The Client Emulation fail-over list was being cleared when a fail-over connection was established. If the fail-over connection failed before the primary server was back on line, service was lost. Q01672454-01 The BSR252 would take a long time to get a new address, if a PC was disconnected from the BSR, connected to another gateway, and then connected back to the BSR in a short period. Q01647312 Multi-proposal would not work if the other end of the Branch Office Tunnel used AES-192 or AES-256 encryption. Q01365147 SIP and H.323 services are no longer shown in the services field in the bandwidth manager, since they cannot be used. Q01437232-01 In the Firewall GUI, the message ‘Configuration updated successfully.’ is now displayed when a change is made. Q01474760 The Nortel contact information was updated. Q01493182 Minor corrections were made to On-Line Help and GUI text. Q01450624, Q01454393, Q01467346, Q01467652, Q01513494 In the System»General GUI page, entries made in the System Name and Domain Name would disappear when the DNS Server pull-down menu was selected. Q01641027 The third IP pool in VPN Contivity Client could not be selected. Q01650984 The Content Filter ‘Access Denied’ message was not being displayed properly with Internet Explorer 7. Q01664210 Enhancements Added in this Release In the Traffic Redirect GUI, the Check WAN IP address would be set to 0.0.0.0 to indicate use of the default IP address. It can now also be set blank. Q01472944 VLAN tagged IP packets are now forwarded without changes to the VLAN tag. Q01491894 The GUI for DST configuration is now preset to the North American DST configuration settings. Q01540161 The GUI will now accept a blank PPPoE password. It will display a warning message if it is blank. Q01578888 and Q01586066 The ‘Apply’ button in the Advanced VPN configuration was renamed to ‘Return’, because it doesn’t actually apply the changes that are made. Q01586160 The retry algorithm for Contivity Client Emulation connections was enhanced to address delays caused by an overloaded server. The Contivity Client version reported by the BSR was changed from V2_50 to V2_60, so that Contivity Client Servers can recognize this upgrade to the router firmware. Q01665250