V22UPGDE.txt INFORMATION ON HOW TO PERFORM A SYSTEM UPGRADE ON AN OPTION 11C VERSION 22.O6B SYSTEM USING A VERSION 18.40, 20 OR 21 BACKUP COPY ON DISC & HAVING A PCMIA CARD IN DRIVE A. 18/06/1996 LOGI PASS? 0000 ... NOTE! IT CAN NOW BE IN LOWER OR UPPER CASE. WARNING: THE PROGRAMS AND DATA STORED ON THIS SYSTEM ARE LICENSED TO OR ARE THE PROPERTY OF NT/BNR AND ARE LAWFULLY AVAILABLE ONLY TO AUTHORIZED USERS FOR APPROVED PURPOSES. UNAUTHORIZED ACCESS TO ANY PROGRAM OR DATA ON SYSTEM IS NOT PERMITTED. THIS SYSTEM MAY BE MONITORED AT ANY TIME FOR OPERATIONAL REASONS. THEREFORE, IF YOU ARE NOT AN AUTHORIZED USER, DO NOT ATTEMPT TO LOGIN. >LD 22 ..... (OBTAIN THIS INFORMATION FIRST BECAUSE YOU WILL REQ SLT NEED IT LATER!) TNS 1000 LEFT 986 USED 14 AGNT 1000 LEFT 994 USED 6 ACDN 100 LEFT 88 USED 12 AST 100 LEFT 100 USED 0 BRI DSL 100 LEFT 100 USED 0 LTID 100 LEFT 100 USED 0 DCH 64 LEFT 64 USED 0 AML 16 LEFT 15 USED 1 MOPT 00000 KEY1 70371533 KEY2 66023624 KEY3 65216752 REQ TID SYSTEM ID: 10000149 AUX ID : 10000149 REQ ISSP VERSION 2111 RELEASE 22 ISSUE 6 B + IN-SERVICE PATCHES : 4 PAT# PRS AUTH ID NAME DATE FILENAME 00 bv53230 fix 11E patches 13/6/96 sys2311.p 01 BV52936 SIGL_EAM 13/6/96 dnlddip.p 02 BV52936 DISC 13/6/96 nprdisk.p 03 BV52936 SIGL_EAM 13/6/96 xdideam.p >LD 143 YOU MUST TYPE IN ... "UPGRADE" . SOFTWARE INSTALLATION PROGRAM NOTE! ************************************ THE PCMIA CARD MUST BE Verify Security ID: 10000149 INSTALLED IN DRIVE A. ************************************ Software Installation Main Menu : 1. New Install or Option 11/11E Upgrade - From Software DaughterBoard 2. System Upgrade 3. Utilities 4. New System Installation - From Software Delivery Card [q]uit, [h]elp or [?], - redisplay Enter Selection : 2 Select type of upgrade to be performed : 1. Option 11/11E to Option 11C 2. Upgrade Option 11C to New Software Release 3. Same Release Upgrade [q]uit, [p]revious, [m]ain menu, [h]elp or [?], - redisplay Enter Selection : 1 *** NOTE: The following questions require information on the Keycode Data Sheet. Please have it available. *** *** NOTE: If an External Data Card is being used for this system, please insert it into drive b: Now. *** Meridian 1 Software Rls 2206B will be installed. Select Feature Set You Wish to Enable : 1. UK - General (ntsk99ca) 2. UK - (ntsk99da) 3. Germany - Advanced (ntsk99ea) 4. Switzerland - Advanced (ntsk99fa) 5. Denmark - Full Feature (ntsk99ga) 6. Norway - Full Feature (ntsk99ha) 7. Italy - Full Feature (ntsk99ia) 8. Sweden - Advanced (ntsk99ja) 9. North America - Trial (ntsk99ka) 10. CALA - Advanced (ntsk99la) 11. Asia Pacific - Trial (ntsk99ma) 12. Japan - Adv. (ntsk99na) [q]uit, [p]revious, [m]ain menu, [h]elp or [?], - redisplay Enter Selection : 2 Feature Set Selection : UK - Do you wish to add packages? (y/n/[a]bort) : N Select Option 11/11E Database Source : 1. CCBR Restore File 2. Option 11/11E Software Cartridge [q]uit, [p]revious, [m]ain menu, [h]elp or [?], - redisplay Enter Selection : 1 Warning: you must have an Option 11/11E database. Do you wish to continue? (y/n/[a]bort) : Y Entering RECEIVE mode fReady to receive... (KEY PAGE UP, X MODEM ETC & LOAD IN FLAT FILE) total packets : 217 (WHEN USING PROCOM +) number of retries : 0 receive timeouts : 3 system errors : 0 unknown characters : 0 transfer cancelled : 0 packets received out of sequence : 0 packets with corrupted sequence : 0 packets failed checksum/crc check : 0 incomplete packets : 0 duplicate packets : 0 REMOTE BACKUP file found.. Files successfully transferred into source directory. Database restore and upgrade complete Current ISM Parameters : TNS ( 1000) AGNT ( 1000) ACDN ( 100) AST ( 100) DSL ( 100) LTID ( 100) MOPT ( 0) Do you wish to change any ISM parameters? (y/n/[a]bort) : N Security ID : 10000149 Current AUX ID : 000029 Do you wish to change the AUX ID? (y/n/[a]bort) : Y Press Enter to default to the AUX Id or enter the new Aux Id 10000149 NOTE! New AUX ID : 10000149 AUX ID = SITE ID ON PRE OPT11C Is this correct? (y/n/[a]bort) : Y & THEREFORE CHANGE TO "N" IF YOU ARE RETAINING THE MAIL SECURITY PASSCODES ETC Option 11/11E Upgrade Summary : Security ID : 10000149 Aux ID : 10000149 Feature Set : UK - (ntsk99da) Additional Pkgs : none Database : CCBR Database OLD NEW S/W Release : 2206B 2206B ISM Parameters TNS : 1000 1000 AGNT : 1000 1000 ACDN : 100 100 AST : 100 100 DSL : 100 100 LTID : 100 100 MOPT : 0 0 Is this correct? (y/n/[a]bort) : Y Enter new keycodes : Key 1 : 70371533 Key 2 : 66023624 ..... ENTER YOUR KEYCODES TAKEN FROM LD 22 SLT Key 3 : 65216752 Keycode validation successful. *** WARNING *** A system restart will be invoked as part of the software installation process Are you sure you wish to perform the upgrade? (y/n/[a]bort) : Y Rebooting.... PLEASE BE AWARE THAT THIS PROCESS TAKES ABOUT 25 MINUTES TO PERFORM SO NOW IS THE TIME TO FIND A GOOD BOOK TO READ!. Meridian1 Option 11C Boot initialize. Pre-Boot: 02 dev2.5 Flash Boot: NTDK34AA_r05 dev2.30 Reset Reason: 360=80, LCA=4 SRAM: 128 kBytes DRAM: 8 MBytes, speed=60 ns Security ID: 10000149 type: NT_STD Backup Flash: 1572 kBytes Program Store: 24 MBytes Flash Drive: 8 MBytes Expansion board #1 not installed. Expansion board #2 not installed. Ethernet MAC address: 00.00.75.45.01.55 PCMCIA card installed in drive A. PCMCIA card not installed in drive B. Executing power up self tests Power up self test passed Five seconds to enter CONTROL-I to invoke install setup program. DRAMOS loading from SW Delivery Card due to Install Setup program DRAMOS load from SW Delivery Card successful. *** OS RESTART *** Meridian 1 X11 System Software Release : x112206b Created : Fri Apr 19 18:22:14 PDT 1996 Loaded : 13/6/96 19:17:52 Copyright(C) 1972-1994 Northern Telecom, Inc. All Rights Reserved. VxWorks 5.1.1 Copyright(C) 1984-1994 Wind River Systems, Inc. All Rights Reserved Use of the above software subject to terms of a license agreement U.S. Government users subject to "Restricted Rights" under FAR & DFAR. Loading AUXRES from disk Initialize Network Interface. Network Interface is up. Host : GALTHOR01 IP Address : 47.85.7.135 Sub-netmask : 255.255.0.0 Loading 'rpteng.db' from "a:/p/rpt/rpteng.db" Unable to find startup script. BACKING UP OLD SOFTWARE AND FILES: Backing up flash ROM software modules: Backing up: auxres /-\/-\(13/6/96 19:17:56.966) SRPT730 OS 0: Cold Start Release: x112206b Created: Fri Apr 19 18:22:14 PDT 1996 /-\88783 bytes copied. / Backing up: diskos /-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-493035 bytes copied. \ Backing up: sl1res /-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/3294185 bytes copied. - Backing up: ovlres /-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\1357887 bytes copied. / / Backing up directory record Backing up files /-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/ Done. INSTALLING NEW SOFTWARE AND FILES: Erasing flash ROM /-\/-\/-\/-\/-\/-\ Installing new flash ROM software modules: Programming: auxres /-\/-\/-\ / Programming: diskos /-\/-\/-\/-\/-\/-\/-\/-\/-\/ /-\/- Programming: sl1res /-\/-\/-\/-\/-\/-\/-\/-\/-\ Installing new directory record Installing new files /-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/-\/ Done. Installation completed successfully. Rebooting... Meridian1 Option 11C Boot initialize. Pre-Boot: 02 dev2.5 Flash Boot: NTDK34AA_r05 dev2.30 Reset Reason: 360=80, LCA=4 SRAM: 128 kBytes DRAM: 8 MBytes, speed=60 ns Security ID: 10000149 type: NT_STD Backup Flash: 1572 kBytes Program Store: 24 MBytes Flash Drive: 8 MBytes Expansion board #1 not installed. Expansion board #2 not installed. Ethernet MAC address: 00.00.75.45.01.55 PCMCIA card installed in drive A. PCMCIA card not installed in drive B. Executing power up self tests Power up self test passed Five seconds to enter CONTROL-I to invoke install setup program. DISKOS to be run. Verifying Diskos. *** OS RESTART *** Meridian 1 X11 System Software Release : x112206b Created : Fri Apr 19 18:22:14 PDT 1996 Loaded : 13/6/96 19:35:38 Copyright(C) 1972-1994 Northern Telecom, Inc. All Rights Reserved. VxWorks 5.1.1 Copyright(C) 1984-1994 Wind River Systems, Inc. All Rights Reserved. Use of the above software subject to terms of a license agreement U.S. Government users subject to "Restricted Rights" under FAR & DFAR. Initialize Network Interface. Network Interface is up. Host : GALTHOR01 IP Address : 47.85.7.135 Sub-netmask : 255.255.0.0 Loading 'rpteng.db' from "c:/p/rpt/rpteng.db" Executing startup script "c:/p/etc/startupc". # MISC: RENAME: FOXSTARTC foxstartc = # EDITION AB01, SL1LIB ARUNA.55 (96/02/27 15:32:50) -- CLOSED # Empty startup file for Option 11C use in the field. cd "c:/p/etc" value = 0 = 0x0 Done executing startup script "c:/p/etc/startupc". PATCHES ARE NOW BEING INSTALLED INTO SERVICE Loading retained patch from "c:/u/patch/sys2311.p" Loading retained patch from "c:/u/patch/dnlddip.p" Loading retained patch from "c:/u/patch/nprdisk.p" Loading retained patch from "c:/u/patch/xdideam.p" Activating patch, handle = 0 Modifying a longword at 0x206b5dc8 from 0x0 to 0x10b60912 Modifying a longword at 0x206b5d9e from 0x0 to 0x10b56192 Modifying a longword at 0x206b5d32 from 0x0 to 0x10b657a4 Modifying a longword at 0x206b5cdc from 0x0 to 0x10b657a4 Modifying a longword at 0x206b5ccc from 0x0 to 0x10b67e06 PATCHLOAD at 0x10b51ae8 will be patched to jump to 0x206b5c94 Patch 0 has been activated successfully. Activating patch, handle = 1 Modifying a longword at 0x206b6272 from 0x0 to 0x1086ea5c XTRK_UNIT_MSG at 0x1086e6fc will be patched to jump to 0x206b6218 Patch 1 has been activated successfully. Activating patch, handle = 2 Modifying a longword at 0x206b73ce from 0x0 to 0x11190d50 Modifying a longword at 0x206b73c4 from 0x0 to 0x1118688a Modifying a longword at 0x206b7328 from 0x0 to 0x11190a68 Modifying a longword at 0x206b7142 from 0x0 to 0x11186b16 Modifying a longword at 0x206b6fd2 from 0x0 to 0x1119c29e Modifying a longword at 0x206b6fc4 from 0x0 to 0x1118681e Modifying a longword at 0x206b6f62 from 0x0 to 0x11190d50 Modifying a longword at 0x206b6e4a from 0x0 to 0x1119c29e Modifying a longword at 0x206b6ddc from 0x0 to 0x11190d50 Modifying a longword at 0x206b6d9a from 0x0 to 0x1119c29e Modifying a longword at 0x206b6d92 from 0x0 to 0x11190d50 Modifying a longword at 0x206b6d88 from 0x0 to 0x1119c29e Modifying a longword at 0x206b6d3c from 0x0 to 0x111869a4 Modifying a longword at 0x206b6cb8 from 0x0 to 0x11190a68 Modifying a longword at 0x206b6ca0 from 0x0 to 0x11190a68 Modifying a longword at 0x206b6c96 from 0x0 to 0x11186484 Modifying a longword at 0x206b6c8e from 0x0 to 0x11190a68 Modifying a longword at 0x206b6c7e from 0x0 to 0x1119c5ea Modifying a longword at 0x206b6bf4 from 0x0 to 0x111865fa Modifying a longword at 0x206b6be8 from 0x0 to 0x1118bb32 Modifying a longword at 0x206b6bd0 from 0x0 to 0x111954d6 Modifying a longword at 0x206b6bc2 from 0x0 to 0x11190d50 Modifying a longword at 0x206b6bb2 from 0x0 to 0x11187082 Modifying a longword at 0x206b6b66 from 0x0 to 0x11190c1c Modifying a longword at 0x206b6b48 from 0x0 to 0x1118bbbc Modifying a longword at 0x206b6b40 from 0x0 to 0x11183fbc Modifying a longword at 0x206b6ad0 from 0x0 to 0x111860a2 DISC at 0x1118574c will be patched to jump to 0x206b6a58 Patch 2 has been activated successfully. Activating patch, handle = 3 Modifying a longword at 0x206b8f62 from 0x0 to 0x1140848a Modifying a longword at 0x206b8e5a from 0x0 to 0x11409aba Modifying a longword at 0x206b8daa from 0x0 to 0x113ff06a Modifying a longword at 0x206b8d74 from 0x0 to 0x11409da2 Modifying a longword at 0x206b8c60 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8c02 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8bf2 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8be2 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8bd2 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8b98 from 0x0 to 0x113f3e38 Modifying a longword at 0x206b8b74 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8b1a from 0x0 to 0x11405214 Modifying a longword at 0x206b8afe from 0x0 to 0x11409a78 Modifying a longword at 0x206b8ad8 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8aaa from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8a88 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8a6a from 0x0 to 0x113ff06a Modifying a longword at 0x206b8a4c from 0x0 to 0x113ff06a Modifying a longword at 0x206b8a0a from 0x0 to 0x113f69a8 Modifying a longword at 0x206b89ec from 0x0 to 0x113ff06a Modifying a longword at 0x206b89ce from 0x0 to 0x113ff06a Modifying a longword at 0x206b898c from 0x0 to 0x113f69a8 Modifying a longword at 0x206b895e from 0x0 to 0x113f69a8 Modifying a longword at 0x206b893c from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8900 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b88b0 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8892 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8850 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b882a from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8794 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b876a from 0x0 to 0x113ff06a Modifying a longword at 0x206b8744 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8722 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b86d6 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b86b8 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8696 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8682 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8642 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8620 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b85e4 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8594 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8572 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b8516 from 0x0 to 0x113f69a8 Modifying a longword at 0x206b84f8 from 0x0 to 0x113ff06a Modifying a longword at 0x206b8484 from 0x0 to 0x113feec8 INSIGNALLING at 0x113f5ea0 will be patched to jump to 0x206b843c Patch 3 has been activated successfully. Start SNMP agent Loading SL1 data Processed c:/p/data/view.cfg SYS000 000800 SRPT730 OS 0: Cold Start Release: x112206b Created: Fri Apr 19 18:22:14 PDT 1996 000000 000000 000000 CPU 0 SYSDB RLS/ISS: 2119 LOADED FROM C: DATE/TIME: 1/4/1993 16:41:32 RECS: 24 SEQNO: 0 DATA CONVERSION NOTE! DATA CONVERSION IS NOW TAKING PLACE X11 ISSUE 21.19 TO X11 ISSUE 22.06B CONFIG BCS TEMPLATE PBX TEMPLATE CUST P_AUX_CUST ACUST LTN LTN LINK TN BLKS SYS4718 TN 136 0 0 0 SYS4718 TN 136 0 0 0 SYS4718 TN 136 0 0 0 SYS4718 TN 136 0 0 1 SYS4718 TN 136 0 0 1 SYS4718 TN 136 0 0 1 SYS4718 TN 136 0 0 1 SYS4718 TN 136 0 0 2 SYS4718 TN 148 0 0 0 SYS4718 TN 148 0 0 0 SYS4718 TN 148 0 0 0 SYS4718 TN 140 0 0 2 SYS4718 TN 140 0 0 3 SYS4718 TN 150 0 0 0 SYS4718 TN 141 0 0 1 SYS4718 TN 141 0 0 1 SYS4718 TN 141 0 0 1 SYS4718 TN 141 0 0 2 SYS4718 TN 152 0 0 0 SYS4718 TN 157 0 0 3 SYS4718 TN 160 0 0 0 SCL NCTL GRP DNS CPK NFCR_TREES ASYNCH AML/ELAN VAS BG_TIME BG_CAT DCH ARIES SYS_PARAM XTDT FTC MCAD FCAD FDCT DTI2SYTI DTI2SCAT FFC LAPW SYS4695 DTSL CPND DATA CPND NAME **PROBLEMS FOUND.** DONE SRPT750 INI 0: INI on side 0 due to System Cold Start INI000 00000000 19 36 02 00000000 00000000 00000000 00000000 ? 00000000 DSET000 DOWN LOAD 19 0 0 2 0 0 0 64693 SRPT752 INI 0: INI completed in 9 seconds INI002 0000008F 00000088 INI003 0000009C 000000A0 000000B0 000000B4 000000B8 000000CE >LOGI LOG ONTO SYSTEM AGAIN PASS? WARNING: THE PROGRAMS AND DATA STORED ON THIS SYSTEM ARE LICENSED TO OR ARE THE PROPERTY OF NT/BNR AND ARE LAWFULLY AVAILABLE ONLY TO AUTHORIZED USERS FOR APPROVED PURPOSES. UNAUTHORIZED ACCESS TO ANY PROGRAM OR DATA ON SYSTEM IS NOT PERMITTED. THIS SYSTEM MAY BE MONITORED AT ANY TIME FOR OPERATIONAL REASONS. THEREFORE, IF YOU ARE NOT AN AUTHORIZED USER, DO NOT ATTEMPT TO LOGIN. TTY #00 LOGGED IN 19:36 13/6/1996 >LD 43 EDD EDD016 NO GO. BAD DATA .... THIS WILL HAPPEN ON S/W 2206B BUT SHOULD NOT APPLY ON LATER ONES >LD 43 EDD CLR DB SEQ NUM = 1 CONFIG PHYSICAL MAP BCS TEMPLATE PBX TEMPLATE CUST ACUST CLID LTN TN LTN LNK TN SCL NCTL GRP DNS CPK NFCR TREES ASNCH AML / ELAN VAS BG-TIME BG-CAT DCH ARIES SYSP XPEC XTDT FTC MCAD FCAD FDCT DTI2 FFC LAPW TBAR RCDT TBAR ART TIME DTSL CPND CPND NM SPECIFIC DATA ALARM_MGT CHECKING RECORD COUNT = 0021 Starting internal database backup to internal backup drive Synching drives Updating internal backup Backing up c:/p/sl1/direct.rec Backing up c:/u/disk.sys Backing up c:/p/os/diskoscc.sym Backing up c:/p/sl1/ovlrescc.sym Backing up c:/p/sl1/sl1rescc.sym Backing up c:/u/db/database.rec Backing up c:/u/db/config.rec Backing up c:/u/db/inet.db Backing up c:/u/patch/reten/reten.pch Backing up c:/u/patch/sys2311.p Backing up c:/u/patch/dnlddip.p Backing up c:/u/patch/nprdisk.p Backing up c:/u/patch/xdideam.p Internal backup complete All files are backed up! DATADUMP COMPLETE **** >LD 22 REQ SLT TNS 1000 LEFT 998 USED 2 AGNT 1000 LEFT 1000 USED 0 ACDN 100 LEFT 100 USED 0 AST 100 LEFT 100 USED 0 BRI DSL 100 LEFT 100 USED 0 LTID 100 LEFT 100 USED 0 DCH 64 LEFT 63 USED 1 AML 16 LEFT 15 USED 1 MOPT 00000 KEY1 70371533 KEY2 66023624 KEY3 65216752 REQ TID SYSTEM ID: 10000149 AUX ID : 10000149 REQ ISSP VERSION 2111 RELEASE 22 ISSUE 6 B + IN-SERVICE PATCHES : 4 PAT# PRS AUTH ID NAME DATE FILENAME 00 bv53230 fix 11E patches 13/6/96 sys2311.p 01 BV52936 SIGL_EAM 13/6/96 dnlddip.p 02 BV52936 DISC 13/6/96 nprdisk.p 03 BV52936 SIGL_EAM 13/6/96 xdideam.p REQ **** HOW TO DO A BACKUP COPY OF A OPT 11C VERSION 22.06B ONTO DISK >LD 143 CCBR000 .XBK INFO: DEFAULT FLAT OPTION 11C V22.O6 FILE 15/06/1996 09:15AM V22MAIL.BKP SIZE = 61696 bytes R> OK. XVR ......... NOTE YOU MUST DO A XVR TO CHECK THAT ALL IS OK! R> OK. **** >LOGO